Currently, Rotor Crusher For Soy Peptide has gradually entered people's lives, more and more factories, and companies are using the equipment.
Rotor Crusher For Soy Peptide is precisely pulverized with ultrafine powder below the micrometer-level, which provides high performance crushing effects that other forms of crushing equipment can be achieved. After processing, there is more than three different particle size ranges of more than three different particle size ranges, which greatly increase the added value of powder raw materials; there is a wide range of applications in metal and non-metallic fields.
ALPA Carbon Rotor Crusher For Soy Peptide Case Sharing: The company produces superfine and super fine pulveruts in the production of static pressure graphite. After many examinations and experiments, finally selected our AlPA as a cooperative customer, we provide the Rotor Crusher for Soy Peptide provided by it to the carbon crushing particle size, particle size range, yield and other needs. Technical parameters:
Finished granularity: D65: 200 目
Production capacity: 800-1000kg
1, the hammer installation error in the maintenance assembly. When the hammer is turned off, in order to prevent the weight of the rotor from losing balance, all the hammers in the pulverizer must be turned out together, otherwise it will have a strong vibration in the operation.
2, the difference between the weight of the two sets of hammer exceeds 5 grams. The method of excluding is to adjust the weight of the hammer, so that the difference between the two sets of weight is less than 5 grams.
3, individual hammer card is too tight, there is no open in operation. After the stop, turn the observation with hand and find a way to turn the hammer flexible.
4, other parts of the rotor are unbalanced, and the adjustment balance needs to be carefully checked.
5, the spindle bending deformation. The solution is to school straight or replacement.
6, the bearing gap exceeds damage. It is generally used to solve the problem.
7. The bottom angle fixing nut is not fixed in a fixed or running. The solution is tightening.